Property X-FOAM® HBD

back to X-FOAM® HBD
Property Norm Units Value
THICKNESS EN 823 mm 30 - 100
THICKNESS TOLLERANCE       
Thickness  < 50 mm EN 823 / EN 13164 mm -2 / +2
Thickness from 50 to 100 mm EN 823 / EN 13164 mm -2 / +3
LENGTH EN 822 mm 1250
WIDTH EN 822 mm 600

 

 
Property Norm Units Value
DECLARED THERMAL CONDUCTIVITY  D) AND DECLARED  THERMAL RESISTANCE (RD)  

 

λD RD
Thickness 30mm  EN 13164 / EN 12667 λD: W/mK - RD: m2K / W 0,032 0,95
Thickness 40mm EN 13164 / EN 12667 λD: W/mK - RD: m2K / W 0,033 1,20
Thickness 50mm  EN 13164 / EN 12667 λD: W/mK - RD: m2K / W 0,034 1,50
Thickness 60mm EN 13164 / EN 12667 λD: W/mK - RD: m2K / W 0,034 1,80
Thickness 80mm EN 13164 / EN 12667 λD: W/mK - RD: m2K / W 0,035 2,30
Thickness 100mm EN 13164 / EN 12667 λD: W/mK - RD: m2K / W 0,035 2,85
COMPRESSIVE STRESS OR COMPRESSIVE STRENGTH AT 10% DEFORMATION EN 826 kPa ≥ 300
COMPRESSIVE CREEP ((2% FOR TOTAL THICKNESS REDUCTION AFTER EXTRAPOLATION AT 50 YEARS)  EN 1606 kPa 120
DIMENSIONAL STABILITY UNDER SPECIFIED TEMPERATURE (70 °C) AND HUMIDITY CONDITIONS ( 90% H.R. EN 1604 % < 0.5

DEFORMATION UNDER SPECIFIED COMPRESSIVE LOAD AND TEMPERATURE CONDITIONS:  70 °C, 168 hours, 40 kPa

EN 1605 % < 0.5
LONG TERM WATER ABSORPTION BY IMMERSION (28 days) EN 12087 Vol % ≤ 0,7
LONG TERM WATER ABSORPTION BY DIFFUSION
(28 days)
     
Thickness from 30mm to 50mm EN 12088 Vol % ≤ 5
Thickness from 60mm to 100mm EN 12088 Vol % ≤ 3
WATER VAPOUR DIFFUSION RESISTANCE FACTOR (μ)      
Thickness 30mm EN 12086   150
Thickness from 40mm to 100mm EN 12086   100
FREEZE-THAW RESISTANCE      
Thickness from 30mm to 50mm EN 12091 Vol % ≤ 2
Thickness from 60mm to 100mm EN 12091 Vol % ≤ 1
REACTION TO FIRE EN 13501-1 Euroclass E
MAXIUM TEMPERATURE OF USE   °C +75
VOLUME PERCENTAGE OF CLOSED CELLS   % >96