Property |
Norm |
Units |
Value |
DECLARED THERMAL CONDUCTIVITY (λD) AND DECLARED THERMAL RESISTANCE (RD) |
|
|
λD |
RD |
Thickness 30mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,032 |
0,95 |
Thickness 40mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,033 |
1,20 |
Thickness 50mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,034 |
1,50 |
Thickness 60mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,034 |
1,80 |
Thickness 80mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,035 |
2,30 |
Thickness 100mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,035 |
2,85 |
COMPRESSIVE STRESS OR COMPRESSIVE STRENGTH AT 10% DEFORMATION |
EN 826 |
kPa |
≥ 300 |
COMPRESSIVE CREEP ((2% FOR TOTAL THICKNESS REDUCTION AFTER EXTRAPOLATION AT 50 YEARS) |
EN 1606 |
kPa |
120 |
DIMENSIONAL STABILITY UNDER SPECIFIED TEMPERATURE (70 °C) AND HUMIDITY CONDITIONS ( 90% H.R. |
EN 1604 |
% |
< 0.5 |
DEFORMATION UNDER SPECIFIED COMPRESSIVE LOAD AND TEMPERATURE CONDITIONS: 70 °C, 168 hours, 40 kPa
|
EN 1605 |
% |
< 0.5 |
LONG TERM WATER ABSORPTION BY IMMERSION (28 days) |
EN 12087 |
Vol % |
≤ 0,7 |
LONG TERM WATER ABSORPTION BY DIFFUSION
(28 days) |
|
|
|
Thickness from 30mm to 50mm |
EN 12088 |
Vol % |
≤ 5 |
Thickness from 60mm to 100mm |
EN 12088 |
Vol % |
≤ 3 |
WATER VAPOUR DIFFUSION RESISTANCE FACTOR (μ) |
|
|
|
Thickness 30mm |
EN 12086 |
|
150 |
Thickness from 40mm to 100mm |
EN 12086 |
|
100 |
FREEZE-THAW RESISTANCE |
|
|
|
Thickness from 30mm to 50mm |
EN 12091 |
Vol % |
≤ 2 |
Thickness from 60mm to 100mm |
EN 12091 |
Vol % |
≤ 1 |
REACTION TO FIRE |
EN 13501-1 |
Euroclass |
E |
MAXIUM TEMPERATURE OF USE |
|
°C |
+75 |
VOLUME PERCENTAGE OF CLOSED CELLS |
|
% |
>96 |
|