Property |
Norm |
Units |
Value |
DECLARED THERMAL CONDUCTIVITY (λD) AND DECLARED THERMAL RESISTANCE (RD) |
|
|
λD |
RD |
Thickness 60mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,034 |
1,75 |
Thickness 80mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,035 |
2,25 |
Thickness 100mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,035 |
2,85 |
Thickness 120mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,036 |
3,30 |
Thickness 140mm |
EN 13164 / EN 12667 |
λD: W/mK - RD: m2K / W |
0,037 |
3,75 |
COMPRESSIVE STRESS OR COMPRESSIVE STRENGTH AT 10% DEFORMATION |
EN 826 |
kPa |
≥ 250 |
DIMENSIONAL STABILITY UNDER SPECIFIED TEMPERATURE (70ºC) AND HUMIDITY CONDITIONS (90% R.H) |
EN 1604 |
% |
< 0.5 |
DEFORMATION UNDER SPECIFIED COMPRESSIVE LOAD AND TEMPERATURE CONDITIONS: 70 °C, 168 hours, 40 kPa |
EN 1605 |
% |
< 0.5 |
LONG TERM WATER ABSORPTION BY IMMERSION (28 days) |
EN 12087 |
Vol % |
≤ 0,7 |
LONG TERM WATER ABSORPTION BY DIFFUSION
(28 days) |
EN 12088 |
Vol % |
≤ 3 |
WATER VAPOUR DIFFUSION RESISTANCE FACTOR (μ) |
EN 12086 |
|
100 |
FREEZE-THAW RESISTANCE |
EN 12091 |
Vol % |
≤ 1 |
REACTION TO FIRE |
EN 130501-1 |
Euroclasse |
E |
MAXIUM TEMPERATURE OF USE |
|
°C |
+75 |
VOLUME PERCENTAGE OF CLOSED CELLS |
|
% |
>96 |
|