Property |
Norm |
Units |
Value |
THERMAL DECLARED CONDUCTIVITY (λD) OF THE INSULATION |
|
|
|
Thickness 40mm |
EN 13164 / EN12667 |
W/mK |
0,033 |
Thickness from 50mm to 60mm |
EN 13164 / EN12667 |
W/mK |
0,034 |
Thickness from 80mm to 100mm |
EN 13164 / EN12667 |
W/mK |
0,035 |
THERMAL DECLARED RESISTANCE (RD) OF THE PANEL X-FOAM WR OSB |
|
|
|
Thickness 10+40+10 mm |
|
m2K/W |
1,36 |
Thickness 10+50+10 mm |
|
m2K/W |
1,71 |
Thickness 10+60+10 mm |
|
m2K/W |
2,00 |
Thickness 10+80+10 mm |
|
m2K/W |
2,51 |
Thickness 10+100+10 mm |
|
m2K/W |
3,04 |
COMPRESSIVE STRENGTH AT 10% OF THE INSULATION |
EN 826 |
kPa |
≥ 200 |
DIMENSIONAL STABILITY UNDER SPECIFIED TEMPERATURE (70 ºC) AND HUMIDITY CONDITIONS (90% R.H.) OF THE INSULATION |
EN 1604 |
% |
< 0.5 |
LONG TERM WATER ABSORPTION BY IMMERSION (28 days) OF THE INSULATION |
EN 12087 |
Vol % |
≤ 0,7 |
LONG TERM WATER ABSORPTION BY DIFFUSION (28 days) OF THE INSULATION |
|
|
|
Thickness 40mm |
EN 12088 |
Vol % |
≤ 5 |
Thickness from 50 to 100mm |
EN 12088 |
Vol % |
≤ 3 |
WATER VAPOUR DIFFUSION RESISTANCE FACTOR (μ) |
|
|
|
Water vapour diffusion resistance factor of the thermal insulation |
EN 12086 |
|
80 |
Water vapour diffusion resistance factor of the panel X-FOAM WR OSB |
EN 12086 |
|
> 100 |
REACTION TO FIRE OF THE THERMAL INSULATION |
EN 130501-1 |
Euroclasse |
E |
MAXIUM TEMPERATURE OF USE |
|
°C |
+75 |