Property X-FOAM® WR

back to X-FOAM® WR
Property Norm Units Value
THICKNESS OF EACH SUPPORT   mm 10
INSULATION THICKNESS EN 823 mm 40 - 50 - 60 - 80 - 100
INSULATION THICKNESS TOLERANCE      
Thickness from 40 to 100mm EN 823 / EN 13164 mm -1,5 / +1,5
LENGTH   mm 2480
WIDTH   mm 1200

 

Property Norm Units Value
THERMAL DECLARED CONDUCTIVITY (λD) OF THE INSULATION      
Thickness 40mm EN 13164 / EN12667 W/mK 0,033
Thickness from 50mm to 60mm EN 13164 / EN12667 W/mK 0,034
Thickness from 80mm to 100mm EN 13164 / EN12667 W/mK 0,035
THERMAL DECLARED RESISTANCE (RD) OF THE PANEL X-FOAM WR OSB      
Thickness 10+40+10 mm   m2K/W 1,36
Thickness 10+50+10 mm   m2K/W 1,71
Thickness 10+60+10 mm   m2K/W 2,00
Thickness 10+80+10 mm   m2K/W 2,51
Thickness 10+100+10 mm   m2K/W 3,04
COMPRESSIVE STRENGTH AT 10% OF THE INSULATION EN 826 kPa ≥ 200
DIMENSIONAL STABILITY UNDER SPECIFIED TEMPERATURE (70 ºC) AND HUMIDITY CONDITIONS (90% R.H.) OF THE INSULATION EN 1604 % < 0.5
LONG TERM WATER ABSORPTION BY IMMERSION (28 days) OF THE INSULATION EN 12087 Vol % ≤ 0,7
LONG TERM WATER ABSORPTION BY DIFFUSION (28 days) OF THE INSULATION      
Thickness 40mm EN 12088 Vol % ≤ 5
Thickness from 50 to 100mm EN 12088 Vol % ≤ 3
WATER VAPOUR DIFFUSION RESISTANCE FACTOR (μ)      
Water vapour diffusion resistance factor of the thermal insulation EN 12086   80
Water vapour diffusion resistance factor of the panel X-FOAM WR OSB EN 12086   > 100
REACTION TO FIRE OF THE THERMAL INSULATION EN 130501-1 Euroclasse E
MAXIUM TEMPERATURE OF USE   °C +75